FLUIDICS FOR RESEARCH & DEVELOPMENT
CONDITIONED REFUELING SYSTEMS
The Technics line of mobile refueling systems provide an integrated package for precision temperature and rate controlled fuel delivery.
- Temperatures from 20 to 150°F with total system accuracy of +/-2°F
- Rapid heat up, cool down: 100 gallons, 10°F/10 minutes
- Flowrates to 4-20 GPM accurate to +/- 0.3 GPM. Other flowrates available
- Sealed and blanketed fuel storage
- Suitable for all fuels: Diesel, M-85, JP-8
- Leak, pressure, and temperature interlocks
- Fully programmed Windows based control & data acquisition
- Circulating fuel up to nozzle insures equal temperatures throughout system
- Automatic flowrate step change or ramping for specialty refueling tests
- Variable speed fuel pump Hazardous area rated, Class I Div. 2, Group D. / Div. 1 optional
- Automatically stirs tank in standby to prevent temperature stratification
- Integral vapor recovery system
- Vapor flow control optional